Standards for workers

ICNIRP, “International Commission on Non-Ionizing Radiation Protection”, is an independent international commission recognised by the World Health Organisation (WHO).

The main objective of ICNIRP is to establish guidelines for limiting exposure to electric and magnetic fields (EMF) that will provide protection against all established adverse health effects.

Guidelines are based on the following:

  • Well-established effects (from perception of a slight tingling on the surface of the skin to real annoyance) may be caused by exposure to low-frequency electric fields.
  • Induction of phosphenes in the retina by low-frequency magnetic fields can be used as a model to put forward induced electric fields’ effects on the central nervous system.

Basic restrictions

Basic restrictions for 50 Hz fields are the values of the internal electric field strength considered as acceptable for people’s well-being. 

For occupational exposure, the maximal value of the internal electric field is:

  • in the central nervous system (CNS: brain and retina): 0,1 V/m
  • in non-CNS tissues (other part of the head and anywhere in the body): 0,8 V/m

Reference levels

Values of induced electric fields are translated into electric quantities allowing direct measurement: external electric and magnetic field strength, magnetic flux density and contact currents. They are reference levels.
The reference levels are obtained from the basic restrictions by mathematical modelling.

The reference levels for exposure to 50 Hz electric and magnetic fields of workers are:

  • Electric field: 10 kV/m
  • Magnetic field: 800 A/m
  • Magnetic flux induction: 1000 µT

The reference level for 50 Hz contact currents is 1 mA.

As mentioned by ICNIRP, “compliance with the reference level will ensure compliance with the relevant basic restriction”. If the measured or calculated value exceeds the reference level, it does not necessarily follow that the basic restriction will be exceeded.


For occupational exposure, the European Parliament and the Council adopted in 2013 (26 June) Directive 2013/35/EU repealing Directive 2004/40/EC on minimum health and safety requirements regarding the exposure of workers to the risks arising from physical agents (electromagnetic fields).

The Member States shall bring into force the laws, regulations and administrative provisions necessary to comply with this Directive no later than 1st July 2016.

The action values and limit values in this directive are based on the 2010 ICNIRP Guidelines (see above).


These guidelines have been drawn up to prevent the harmful effects of exposure to electromagnetic fields in the 0–3 kHz range. The guidelines apply to exposure of the general public, as well as to people in controlled environments.

Basic restrictions

Internal electric fields

  • Brain : 44.3 mV/m
  • Heart : 0.943 V/m
  • Hands, wrists, feet, ankles : 2.10 V/m
  • Other :  2.10 V/m  

Maximum permissible exposure (MCE)

50 Hz magnetic field

  • Head and torso : 2.71 mT
  • Arms and legs:  75.8 mT  

Federal public service employment, labour and social dialogue

The Royal decree of June 10, 2016, transposes into Belgian law Directive 2013/35/EU of the European Parliament and of the Council of June 26, 2013, concerning the minimum health and safety requirements regarding the exposure of workers to risks arising from physical agents (electromagnetic fields).

Following this legislation, the book V, Title 7 of the Workplace Well-Being Code is dedicated to exposure to electromagnetic fields in the workplace.

In 2018, the Dutch National Institute for Public Health and the Environment (Rijksinstituut voor Volksgezondheid en Milieu (RIVM)), published a document were they compare international policies on electromagnetic fields (power frequency and radiofrequency fields).