Standards for the general public
ICNIRP
The International Commission on Non-Ionizing Radiation Protection (ICNIRP) is an independent commission recognised by the World Health Organisation (WHO).
The main objective of the ICNIRP is to establish guidelines for limiting exposure to electric and magnetic fields (EMF) that will provide protection against all established adverse health effects. These guidelines are based on the following:
- Well-established effects (from perception of a slight tingling on the surface of the skin to real annoyance) may be caused by exposure to low-frequency electric fields.
- Induction of phosphenes in the retina by low frequency magnetic fields can be used as a model to put forward induced electric fields effects on the central nervous system.
In view of the uncertainty inherent in the scientific data, reduction factors have been applied in establishing the exposure guidelines. A reduction factor is applied for the exposure of the general public (in comparison with occupational exposure). It is intended to take into account its heterogeneity (age diversity, the health status of the public, environmental conditions, personal sensitivity).
Basic restrictions for 50 Hz fields are the values of the internal electric field strength considered as acceptable for people’s well-being.
For general public exposure, the maximal value of the internal electric field is:
- in the central nervous system (CNS: brain and retina): 0,02 V/min
- non-CNS tissues (other part of the head and anywhere in the body): 0,4 V/m
Values of induced electric fields are translated into electric quantities allowing direct measurement: external electric and magnetic field strength, magnetic flux density and contact currents. They are reference levels that are obtained from the basic restrictions by mathematical modeling. An additional reduction factor of 3 is applied to these calculated values to allow for dosimetric uncertainty.
The reference levels for exposure to 50 Hz electric and magnetic fields of the public (everyday exposure) are:
- Electric field: 5 kV/m
- Magnetic field: 160 A/m
- Magnetic flux induction: 200 µT
The reference level for 50 Hz contact currents is: 500 µA.
As mentioned by ICNIRP, “compliance with the reference level will ensure compliance with the relevant basic restriction”. If the measured or calculated value exceeds the reference level, it does not necessarily follow that the basic restriction will be exceeded.
European Union
For general public exposure, the Council of the European Union adopted in 1999 the recommendation 1999/519/EG on the limitation of the general public to electromagnetic fields. Only established acute effects were used as a basis for the proposed exposure restrictions.
The basic restrictions are set to account for uncertainties related to individual sensitivities, environmental conditions, and for the fact that the age and health status of members of the public vary. In addition, safety factors of about 50 between the threshold values for acute effects and the basis restrictions were applied.
Depending on frequency, various physical quantities (dosimetric/exposimetric quantities) are used to specify the basic restrictions on electromagnetic fields. Between 1 Hz and 10 MHz basic restrictions are provided for current density to prevent effects on nervous system functions.
| At 50 Hz, the basic restriction is set to 2 mA/m² (rms). |
The reference level on contact current were set to account for the fact that the threshold contact currents that elicit biological responses in adult women and children are approximately two-thirds and one-half, respectively, of those for adult men.
- Magnetic flux density: 100 µT rms
- Electric field: 5 kV/m rms
- Contact currents: 500 µA
Note of the Concil: As noted above, only established effects of acute exposure are used as basis for the proposed exposure restrictions. “However, since there are safety factors of about 50 between the threshold values for acute effects and the basis restrictions, this recommendation implicitly covers possible long-term effects in the whole frequency range.”
On 20 February 2013, the European Commission held a workshop in Brussels on “Risk Communication – Electromagnetic Fields and Human Health”.
Here are the conclusions of the presentation regarding the role of the EU institutions in EMF protection:
“Regarding the protection of the general public from potential effects of EMF, the EU Treaties give the primary responsibility to the Member States and do not confer the Commission competence to legislate. The Council Recommendation on EMF exposure limits (1999/519/EC) was adopted to propose a common protective framework to guide the action of Member States in the hope to bring coherence among the various national approaches. Following the subsidiarity principle (apart from workers’ protection), the role of the EU institutions is limited to provision of independent scientific advice (SCENIHR’s work) and to coordination and harmonization of the Member States policies as well as promotion of the best practices.”
IEEE
The Institute of Electrical and Electronics Engineers (IEEE) developed guidelines to prevent the harmful effects of exposure to electromagnetic fields in the 0–3 kHz range. The guidelines apply to exposure of the general public.
Internal electric fields
- Brain : 14.7 mV/m
- Heart : 0.943 V/m
- Hands, wrists, feet, ankles : 2.10 V/m
- Other : 0.701 V/m
50 Hz magnetic field
- Head and torso : 904 µT
- Arms and legs: 75.8 mT
50 Hz electric field
- In general : 5 kV/m
- Under power lines (normal load): 10 kV/m
Belgium
| The value of the undisturbed electric field, in undisturbed regime, generated by any electrical installation involved in the transmission or distribution of electrical energy, must remain lower than the following values measured at 1.5 m above the ground (or home): Inhabited area, or area intended for habitation on sector plan: 5 kV/mOverhangs of roads: 7 kV/mOther places: 10 kV/m |
There is to date no particular Belgian legislation concerning exposure to power frequency magnetic induction.
The order on indoor pollution (11 June 2004) provides quality values for chemical, physical and biotic factors. A new version has been published on the 13th of July 2018. This new version specifies a new guide value (0.4µT) and a new intervention (20µT), document available : here.
Furthermore, to protect against acute health effects from outdoor sources, a new standard (VLAREM) has been added with an instantaneous exposure limit (100µT). With regard to long-term exposure, measures based on European commission guidelines have been taken, limiting the average annual exposure to 0.4 µT. Information available: here.
- Guide value: 0.4 µT
- Intervention: 20 µT
- instantaneous exposure limit: 100 µT
- Average annual exposure limit: 0.4µT
The order on operating conditions of static transformers (nominal power between 250 and 1000 kVA) (9 September 1999) specifies:
- The value of the undisturbed electric field, in undisturbed regime: < 5 kV/m
- Outside the substation, the value of 50/60 Hz magnetic induction is limited to 100 µT (permanent exposure) and 1000 µT (acute exposure).
The following requirement applies to all new static transformers:
In all premises in which children under 15 are likely to stay, magnetic induction value at 50/60 Hz generated by the transformer is limited to a guide value of 0.4 µT (based on a daily average of 24 hours), excluding areas influenced by cables before they enter the plot of land with the transformer.
If this requirement cannot be met, it is beyond the applicant’s duty to provide the proof of all potential technical or economical impossibilities and to mention the lowest achievable level according to the BATNEEC principle (Best Available Technology Not Entailing Excessive Cost), but magnetic induction value can never exceed 10 µT.
The Decree on Indoor Air Quality of 31 January 2019 was amended on 8 February 2024 by the addition of a “very low frequency electromagnetic radiation” component).
The Decree of the Walloon Government of 30 May 2024 therefore establishing the guide and intervention values referred to in the Decree of 31 January 2019 sets the following values:
Chronic exposure:
- Guide value: 0.4µT
- Intervention value : 20 µT
Acute exposure:
- Guide value : /
- Intervention value: 100µT
Order on operating conditions of static transformers (nominal power equal to or greater than 1.500 kVA) (1 December 2005):
- Outside the substation (permanent exposure), the value of the 50 Hz undisturbed electric field, in undisturbed regime, is limited to < 5 kV/m
- Outside the substation (permanent exposure), the value of the 50 Hz undisturbed magnetic field, in undisturbed regime, is limited to < 100 μT
Order on stationary batteries (product of the capacity in Ah and the voltage in V greater than 10 000) (12 December 2006 (add. 22 January 2007)):
- Outside the electrical safety area of the inverter system (permanent exposure), the value of the 50 Hz undisturbed electric field, in undisturbed regime, is limited to < 5 kV/m
- Outside the electrical safety area of the inverter system (permanent exposure), the value of the 50 Hz undisturbed magnetic field, in undisturbed regime, is limited to < 100 μT
Royal Decree of 28 February 2007 on electromagnetic compatibility (which came into force on 20 July 2007).
(Directive 2004/108/EC of the European Parliament and of the Council:
http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2004:390:0024:0037:fr:PDF)
Electromagnetic compatibility is the ability of a device, apparatus or system to function satisfactorily within its electromagnetic environment without itself generating electromagnetic disturbances that are intolerable to anything else in that environment.
Electromagnetic disturbances are electromagnetic phenomena capable of causing operational disruption to a device, apparatus or system. An electromagnetic disturbance may take the form of electromagnetic noise, an unwanted signal or a change in the propagation medium itself.
This Order applies to apparatus capable of generating electromagnetic disturbances or whose operation is likely to be affected by such disturbances. Radio equipment used by amateur radio operators is excluded from the scope of this Order, unless the equipment is commercially available.
Apparatus must be constructed in such a way that:
(a) the electromagnetic disturbances generated are limited to a level that allows radio and telecommunications equipment and other apparatus to operate in accordance with their intended purpose;
(b) the apparatus has an adequate level of intrinsic immunity to electromagnetic disturbances, enabling it to operate in accordance with its intended purpose.
Equipment may only be placed on the market or put into service if it bears the CE marking, which indicates its compliance with all the provisions of this Order.
Equipment is presumed to meet the protection requirements where it complies with harmonised European standards.
Note
In 2018, the Dutch National Institute for Public Health and the Environment (Rijksinstituut voor Volksgezondheid en Milieu (RIVM)), published a document were they compare international policies on electromagnetic fields (power frequency and radiofrequency fields).
Links and references
- Guidelines from ICNIRP for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz)
- ICNIRP guidelines, factsheet: here
- 1999/519/EC: EU Council Recommendation of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz)
- Comparison of international policies on electromagnetic fields (power frequency and radiofrequency fields)