FAQ on guidelines and regulations

What is the minimal height to respect between a house (roof) and high voltage cables? Where can I find the regulation in this matter?

These questions are adressed in the article 164 of the RGIE (Règlement Général des Installations Electriques). Further information can be found at the site of the Belgian FPS Economy, SMEs, independent Professions and Energy (partially developped in English, complete in French and Dutch, tab Energie – Electricité – Contrôle des installations électriques).

The company that owns the line must of course respect these standards. In case of a building under an existing line, the builder must also respect these constraints.

If you would like an answer independent from the transmission system operator, you should contact an inspection, verification, testing and certification company. You can also contact your electricity supplier (see your electricity invoice).

The distance between the cable and the roof depends on the voltage of the line and of course on the location of the house along the span, and also the ambient temperature, the sun and the wind. An additional safety distance is also adopted in case of overvoltage. When introducing a new regulation, the more critical case is considered, i.e. maximal load in the line, maximal insolation (around 1000 W/m2), maximal ambient temperature and a low wind of 0.6 m/s.

For example, according to the article 164 of the RGIE, the minimum distance between the roof of a house and a low voltage line (400 V) is 2 m. The higher the voltage of the line is, the higher the distance will be.

 I would like to know what is the regulated distance from high voltage powerline we can build a house. Are there some national or Community regulations (directive), and if it is so, which one?

In Belgium, there are currently no regulations restricting where houses may be built. It is therefore possible to build a house just below a boundary line.

Regulatory restrictions relate to the vertical and horizontal safety distances that must be observed when in the vicinity of a power line. These are set out in the RGIE (Article 164) according to the voltage level and a number of parameters – see further information on the website of the Service Public Fédéral – Economie, PME, Classes moyennes et Energie / Onglet Energie – Electricité – Contrôle des installations électriques.

How far from overhead power line should humans remain, so as not to take more risk than in their normal everyday life?

Knowing that maximal magnetic field level under an overhead powerline (measured with respect to the legal safe distance) is always under 50 microT and that international guidelines advise not to exceed 100 microT, we can state there is no safe distance to respect with regard to magnetic fields.

However, if you desire to keep out of the range of influence of the line where the mean level goes up the epidemiological cut-off point of 0.4 microT, you must be aware of the load of the line, which varies greatly over time and from one line to another. On average, we can evaluate the half width (i.e. the distance from the axis of the line) at about 80 m for a 380 kV powerline, 40 m for 150 kV, and 15 m for 70 kV.

Is it possible to build a family dwelling under a 15 kV powerline? If not, what are the regulations and the distance to be respected?

This authorization varies from country to country. In Belgium, in consideration of population density (one of the highest in the world), it is possible to build a house under a powerline.

Safety distances are imposed by RGIE / AREI (*) (Règlement Général des Installations Electriques / Algemeen reglement voor elektrische installaties) and can be obtained on demand to the electrical society (Elia in Belgium) that is responsible of the line. It depends of course of the voltage of the line but also of the conditions of installation (sag of the conductor in case of maximale temperature).

If you construct such a building, it is essential to design your wiring strickly in compliance, especially by installing an excellent ground wiring, by the grounding of all metallic structures (heater, pipes, drainpipe…). We advise you to consult a certified organization.

(*) http://economie.fgov.be/ (in French or in Dutch)
(Energie – Electricité – Contrôle des installations électriques)