Recommendations are given to prevent harmful effects in human beings exposed to electromagnetic fields in the frequency range of 0-3 kHz. The recommendations are intended to apply to exposures of the general public, as well as to individuals in controlled environments (>>).
IEEE standards
Basic restrictions
Internal electric fields
Part of body | Limit for public exposures (50 Hz) |
---|---|
Brain |
14.7 mV/m |
Heart |
0.943 V/m |
Hands, wrists, feet, ankles |
2.10 V/m |
Other |
0.701 V/m |
Maximum permissible exposures (MCE)
50 Hz magnetic field
Part of body | Limit for public exposures (50 Hz) |
---|---|
Head and torso |
904 µT |
Arms and legs |
75.8 mT |
50 Hz electric field
Limit for public exposures (50 Hz) | |
---|---|
In general |
5 kV/m |
Under powerlines (normal load) |
10 kV/m |